ANAPF Active Power Filter

ANAPF Active Power Filter

 

● 380V±15%,50Hz±2%

● Full response time ≤ 5ms

● 30A, 50A, 75A,100A or 150A

● RS485(Modbus-RTU)or Ethernet(Modbus-TCP)

● Frozen data

● 2-51st Harmonics

description1
Zipper closure 1/5 zip athletic pullovers for men. Stretchy, lightweight, fast-drying fabric for superior performance. REGULAR FIT - US standard sizes. An athletic fit that sits close to the body for a wide range of motion, designed for optimal performance and all day comfort. FEATURES - Quarter zip closure;Thumbholes on long sleeves to keep them in place during workout
INFORMATION
01 Function

 
Dimension(L*W*H)
450*622*201mm
 
Response time
Full response time≤5ms,Instantaneous response time≤100μs
 
Total harmonic compensation rate
≥ 97%,3th/5th/7th/9th independent compensation rate ≥ 98%
 
Self-loss
≤2%
 
Efficiency
≥98%
 
Switching frequency
20KHz

 

 
 
02 Wiring
 
 
 
 

03 Network

 
 
 
PARAMETERS
Rated voltage Rated insulation voltage 660V
Rated working voltage 220V (single phase three wire system), 380V (three phase five wire system)
Rated impact withstand voltage Uimp 8kV
Overvoltage class III
Pollution levels Class 2
Rated frequency 50HZ
Rated current Rated current 100A to 630A(configurable as request)
Rated short-time withstand current 6kA
EMC Electromagnetic compatibility Industrial 2 class
insulation resistance ≥10MΩ
dielectric strength 1min 2500V
Grounding Resistance ≤0.1Ω
structural characteristics
Size(mm) width 600、800、1000
height 2000、2200
depth 600、800、1000、1100
oscillation specification 5Hz~50Hz,amplitude 20mm/s
Cabinet color RAL9004
Surface treatment Epoxy resins electrostatic powder spraying
Protection level IP20
Componenets installation in cabinet Fixed type or plug-in type
Installation Floor type
Installation place indoor
Material specifications frame RKIII
mounting plate ALZINC
Door plank Mesh or glass doors
Output switch 6A~63A(single phase or three phase)
Output circuit 21-84 channels
alarm style Audible and visual alarm
Communication port RS485,RS232 and LAN(ethernet) optional
Main feeder monitoring parameters

Three-phase voltage, current, frequency, zero sequence current, active/reactive power, power factor,

Active/reactive energy, total harmonic content, 2~15 harmonics, etc

Main feeder alarm item

Three phase overvoltage/undervoltage, phase deficiency, imbalance, three phase current

overcurrent, zero sequence overcurrent, high/low frequency

Outgoing circuit  Outgoing voltage, current, load percentage, switch on/off state, etc
Sub-alarm item Outgoing circuit overload warning, outgoing open circuit alarm lamp, etc
Ground/zero connection Single floor row/zero row
Feeder and outgoing mode Up incoming or down incoming
Two circuits system Optinal
Environment operating temperature -5℃ to 40℃
Relative humidity ≤93%RH(25℃±5℃时)
altitude ≤2000m
storage

Well ventilated, temperature -25℃ ~ +55℃, relative humidity ≤85%, the surrounding environment

does not contain corrosive gas, no harmful chemicals and gases in the warehouse