AMC16-DETT Base Station DC Energy Meter For 5G Tower

AMC16-DETT Base Station DC Energy Meter For 5G Tower

 

•DC rated voltage: 1 channel: -48VDC
•Accuracy:1%In≤I≤10%In error±2.5%; I>10%In error±2%
•RS485(MODBUS-RTU)
•DIN 35 mm
•Designed for base stations

description1
Zipper closure 1/5 zip athletic pullovers for men. Stretchy, lightweight, fast-drying fabric for superior performance. REGULAR FIT - US standard sizes. An athletic fit that sits close to the body for a wide range of motion, designed for optimal performance and all day comfort. FEATURES - Quarter zip closure;Thumbholes on long sleeves to keep them in place during workout
INFORMATION
01 Function

 
Communication
RS485(Modbus-RTU)
 
Rated U and I
Total 200A/5V
 
Accuracy
1%In≤I≤10%In error±2.5%;I>10%In error±2%
 
Voltage range
-40V~-60VDC
 
Power consumption
≤2W( no hall power supply output)
 

 

 

 
Installation
DIN 35 mm
 
Dimension(L*W*H)
89.7*87.8*52mm
 
Clock
≤0.5S/d(23℃), ≤1S/d(-20℃-60℃)
 
Current
1.2 times continued

 

 
 
02 Dimension
 
03 Wiring
 

04 Network

PARAMETERS
Input
DC rated voltage
1 channel: 0-48VDC
DC current

6 channels hall sensors: total 200A/5V, China Telecom, China Mobile, China

Unicom and the 1st channel reserve 50A/5V, 2nd channel reserve 100A/5V

Commercial power monitoring
1 channel: 0-5VDC
Overload capacity

Voltage: 1.2 times continued, 2 times continued 1s;

Current: 1.2 times continued, 10 times continued 1s

Accuracy

(superposition hall sensors)

1%ln≤ l ≤10% ln error±2.5%; l>10%ln error±2%
Measurement resolution
Voltage: 0.01V, Current: 0.01A, Power: 0.01kw, Energy: 0.01kwh
Functions
Basic function

Monitor device system time, total voltage, total current, power energy, each channel voltage, current, power, energy; LED display, RS485 communication

Metering function

Start current: under rated voltage, when the load current value of the meter doesn't exceed 1% of the max current,the meter start.

Shunt running current: when there is no current in the current circuit of the meter, and 85%-125% of the rated voltage is applied on the voltage circuit, the calculator shall not have more than one digital change.

Alarm function
DC under-voltage, DC over-voltage, one power down, module voltage loss, metering branch error, internal program error, clock error, memory failure, AC input power failure.