Mar 31, 2022
I Background
In recent years, in response to global warming and climate change caused by greenhouse gas emissions,many countries have focused on promoting electric vehicles to replace traditional fuel vehicles. And the construction of charging piles is very important in the promotion of new energy vehicles.Therefore, a large number of charging pile projects have emerged around the world.
II Project Overview
The company is a charging pile manufacturer located in South Korea, using our DC energy meter DJSF1352-RN to match their DC charging pile. After using it for a period of time, they’re very satisfied with the quality of our products.
III DJSF1352-RN introduction
IV Acrel energy meters for charging pile Introduction
Item |
Shape |
Type |
Function |
Single Phase AC Energy Meter |
ADL10-E |
Din rail mounted; single-phase 60A, 50/60Hz input; measurement of electrical parameters such as voltage, current, power, energy; RS485 communication (Modbus protocol). |
|
ADL100-ET |
Din rail mounted; single-phase 60A, 50/60Hz input; measurement of electrical parameters such as voltage, current, power, energy; RS485 communication (Modbus protocol). energy pulse output; optional multi tariff. |
||
ADL200 |
Din rail mounted; single-phase 80A, 50/60Hz input; measurement of electrical parameters such as voltage, current, power, energy, etc.; RS485 communication (Modbus protocol); energy pulse output; optional multi tariff. |
||
Three Phase AC Energy Meter |
ADL400 |
Din rail mounted; three-phase 80A, 50/60Hz input; measurement of electrical parameters such as voltage, current, power, energy; RS485 communication (Modbus protocol); energy pulse output; optional multi tariff. |
|
ADL3000-E |
Din rail mounted; three-phase 80A, 50/60Hz input; measurement of electrical parameters such as voltage, current, power, energy; RS485 communication (Modbus protocol); energy pulse output; optional multi tariff. |
||
DC Energy Meter |
PZ72(L)-DE |
Panel mounted, measure DC voltage, current, power; measure DC energy; direct connect voltage 0-1000V; current measurement support 75mV output of shunt, support 0-5V, 0-20mA output of hall; RS485(Modbus protocol) |
|
DJSF1352 |
Wall mounted, measure DC voltage, current, power; measure DC energy; direct connect voltage 0-1000V; current measurement supports 75mV output of shunt, supports 0-5V, 0-20mA output of hall; RS485(Modbus protocol) |
||
DJSF1352-RN |
Din-rail mounted, support optional two-channel DC voltage, current, power measurement; measure DC energy; direct connect voltage 0-1000V; current measurement support shunt 75mV output, support Hall sensor 0-5V, 0-20mA output; RS485 communication (Modbus protocol) |
||
Shunt |
AFL-T |
Common Specification: 300A/75mV |
|
Hall Sensor |
AHKC |
Common Specification: 1000A/5V |
October 26, 2016